Introducing MIRRORCLE-6X

Mirrorcle-6X picture



  MIRRORCLE-6X is the world's smallest synchrotron. It is small enough to fit in a most industrial and laboratory environments, yet powerful enough to satisfy many demanding X-ray requirements. MIRRORCLE-6X explores new levels in price vs performance, and makes the possibility of owning a synchrotron a reality.
  European commission have adopted Research Infrastructures to establish "MIRRORCLE EU center" in Europe. Five organizations with Katholieke Universiteit Leuven as a center design beamlines.

MIRRORCLE-6X uses 6 MeV electrons colliding with a tungsten micro target to generate brilliant broadband X-rays via bremsstrahlung. The standard size 1 μm size target can be reduced in size to  0.1 μm for applications that require it. Target size determines X-ray imaging resolution, so target size is important for high quality X-ray imaging.

MIRRORCLE-6X is a production product that is ready to meet your requirements today. Please contact us for more information.

MIRRORCLE-6X Specifications

MIRRORCLE type:
6 MeV model
Electrons circular machineThere is acceleration cavity
Magnet typeElectromagnet
Magnet diameter60 cm
Electron orbit radius15 cm
N-value0.72
Injection methodA half integer resonance
CW Klystron power (Maximum)100W
Harmonics8
Weight0.5 t
Beam lifetime
(When no target, at April, 2007)
600 msec
Injector type
MICROTRON
RF Frequency2.45 GHz
RF Source5 MW compact pulse klystron
Peak current (MAX)100 mA
Injection repetition rate (MAX)400 Hz
Gate width for peak current0.1 μs
Dimensions0.6 m O.D.
Weight0.5 t
Energy range
FIR, EUV,
Hard X-ray (10 - 6000 keV)
Maximum photon power100 W
Density (Brightness) [photons/s/mrad2/0.1% λ]108
Brilliance [photons/s/mrad2/mm2/0.1% λ]1012
Maximum input power130 kVA
Total sizeW100 x D150 x H130 cm
Total weight
1 t
Total weight
1 t
Radiation shieldingOption
*1 MIRRORCLE's X-ray power very much depends on the vacuum pressure.
It will be increased after while.